CLMQQ - HT90-1,CRYSTAL VIOLET SOLUTION (SEE SUPPL)
- MSDS: CLMQQ
- Manufacturer: SIGMA ALDRICH CORP
- Product Name: HT90-1,CRYSTAL VIOLET SOLUTION (SEE SUPPL)
- National Stock Number: 6550-01-449-4352
Product Identification
Product ID:HT90-1,CRYSTAL VIOLET SOLUTION (SEE SUPPL)
MSDS Date:09/10/2001
FSC:6550
NIIN:01-449-4352
Status Code:A
Kit Part:Y
MSDS Number: CLMQQ
Responsible Party
ST LOUIS, MO 63103
US
Emergency Phone: 314-771-5765
Info Phone: 800-505-6275/ 314-771-5765
Cage: 1FPM8
Contractor
Telephone: 800-505-6275/ 314-771-5765
Cage: 1FPM8
Ingredients
METHYL ALCOHOL
CAS: 67-56-1
RTECS: PC1400000
OSHA PEL 260 MG/M3;200 PPM
ACGIH TLV: 262 MG/M3;200 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ETHYL ALCOHOL
CAS: 64-17-5
RTECS: KQ6300000
OSHA PEL 1900 MG/M3;1000 PPM
ACGIH TLV: 1880 MG/M3;1000 PPM
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Health Hazards Acute and Chronic:ACUTE EFFECTS: MAY BE HARMFUL BY
INHALATION, INGESTION, OR SKIN ABSORPTION. CAUSES SKIN IRRITATION.
VAPOR OR MIST IS IRRITATING TO THE EYES, MUCOUS MEMBRANES AND UPPER
RESPIRATORY TRACT. TARGET ORGAN (S): NERVES, EYES, KIDNEYS, LIVER,
HEART.
Effects of Overexposure:ACUTE EFFECTS: MAY BE HARMFUL BY INHALATION,
INGESTION, OR SKIN ABSORPTION. CAUSES SKIN IRRITATION. VAPOR OR
MIST IS IRRITATING TO THE EYES, MUCOUS MEMBRANES AND UPPER
RESPIRATORY TRACT. TARGET ORGAN (S): NERVES, EYES, KIDNEYS, LIVER,
HEART.
First Aid
First Aid:IN CASE OF CONTACT, IMMEDIATELY FLUSH EYES WITH COPIOUS
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. IN CASE OF CONTACT,
IMMEDIATELY WASH SKIN WITH SOAP AND COPIOUS AMOUNTS OF WATER. IF
INHALED, REMOVE T O FRESH AIR. IF NOT BREATHING GIVE ARTIFICIAL
RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. IF SWALLOWED,
WASH OUT MOUTH WITH WATER PROVIDED PERSON IS CONSCIOUS. CALL A
PHYSICIAN. WASH CONTAMIN ATED CLOTHING BEFORE REUSE.
Fire Fighting
Flash Point:=37.8C, 100.F
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER OR APPROPRIATE
FOAM.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING TO PREVENT CONTACT WITH SKIN AND EYES.
COMBUSTIBLE LIQUID.
Unusual Fire/Explosion Hazard:EMITS TOXIC FUMES UNDER FIRE CONDITIONS.
Accidental Release
Spill Release Procedures:EVACUATE AREA. SHUT OFF ALL SOURCES OF
IGNITION. WEAR SELF-CONTAINED BREATHING APPARATUS, RUBBER BOOTS AND
HEAVY RUBBER GLOVES. ABSORB ON SAND OR VERMICULITE AND PLACE IN
CLOSED CONTAINERS FOR DISPOSA L. USE NONSPARKING TOOLS. VENTILATE
AREA AND WASH SPILL SITE AFTER MATERIAL PICKUP IS COMPLETE.
Handling
Handling and Storage Precautions:KEEP TIGHTLY CLOSED. STORE IN A COOL
DRY PLACE. USE NONSPARKING TOOLS. DO NOT BREATHE VAPOR. DO NOT GET
IN EYES, ON SKIN, ON CLOTHING. AVOID PROLONGED OR REPEATED
EXPOSURE. WASH THOROUGHLY AFTER HANDL ING. KEEP AWAY FROM HEAT AND
OPEN FLAME.
Exposure Controls
Respiratory Protection:WEAR APPROPRIATE NIOSH/MSHA-APPROVED RESPIRATOR.
Ventilation:USE ONLY IN A CHEMICAL FUME HOOD.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:SAFETY SHOWER AND EYE BATH. OTHER PROTECTIVE
CLOTHING.
Supplemental Safety and Health
4-PART KIT (SAME NSN) CONSISTING OF: HT30-2-8,TARTRAZINE SOLUTION,
HT90-1,CRYSTAL VIOLET SOLUTION, HT90-2,GRAM'S IODINE SOLUTION, AND
HT90-4, SAFRANIN O SOLUTION.
Chemical Properties
HCC:F4
Appearance and Odor:LIQUID.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, PEROXIDES, ACIDS, ACID CHLORIDES, ACID
ANHYDRIDES, ALKALI METALS, AMMONIA, MOISTURE.
Stability Condition to Avoid:STABLE.
Hazardous Decomposition Products:TOXIC FUMES OF CARBON MONOXIDE, CARBON
DIOXIDE, NITROGEN OXIDES, HYDROGEN CHLORIDE GAS.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:THIS COMBUSTIBLE MATERIAL MAY BE BURNED IN A
CHEMICAL INCINERATOR EQUIPPED WITH AN AFTERBURNER AND SCRUBBER.
OBSERVE ALL FEDERAL, STATE AND LOCAL ENVIRONMENTAL REGULATIONS.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Regulatory
SARA Title III Information:THIS PRODUCT IS SUBJECT TO SARA SEC 313
REPORTING REQUIREMENTS.